Parkside PWS 125 B2 User Manual Page 67

  • Download
  • Add to my manuals
  • Print
  • Page
    / 102
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 66
67
MTGB
from the outlet. Do not touch the cable
before it has been disconnected from
the power supply.
Risk of electric shock!
The replacement of the plug or the con-
nection line must always be executed
by the manufacturer of the electric tool
or his/her customer service in order to
avoid any hazards.
Only use grinding discs where the in-
dicated rotational speed is at least as
high as what has been specied on the
name plate of the device.
Carry out a visual inspection of the
grinding disc before use. Do not use
any damaged or deformed grinding
discs. Replace any damaged or worn
grinding discs.
Make sure that the sparks produced by
grinding do not present a danger, e.g.
reach people or ignite ammable subs-
tances.
Always wear safety goggles, safety
gloves, respiratory protection and ear
protection when grinding, brushing and
cutting.
Never keep the ngers between the
grinding disc and spark protection or in
close proximity to the protective hoods.
There is a risk of crushing.
The rotating parts of the device cannot
be covered due to functional reasons.
Therefore, proceed cautiously and hold
the workpiece rmly in order to avoid
slipping which could cause your hands
to come into contact with the grinding
disc.
The workpiece gets hot during grin-
ding. Do not touch the machined area,
allow it to cool down. There is a risk of
burning. Do not use coolants or the like.
If you are tired or have consumed al-
cohol or tablets, do not work with the
device. Always have a break on time.
Switch the device off and remove the
mains plug
- to loosen a blocked insertion tool,
- if the connection line is damaged or
entangled,
- in case of unusual sounds.
RESIDUAL RISKS
Even if properly operating and handling
this electric tool, some residual risks will
remain. Due to its construction and build,
this electric tool may present the following
hazards:
a) Cuts
b) Ear damage if working without ear pro-
tection.
c) Damage to your health caused by swin-
ging your hands and arms when opera-
ting the appliance for longer periods of
time or if the unit is not held or maintai-
ned properly.
d) Health injuries which result from swin-
ging hand and arm, in the event that
the device is used over a longer period
of time or is not used and maintained
properly.
Warning! During operation, this
electric tool generates an electro-
magnetic eld which, under certain
circumstances, may impair the
functionality of active or passive
medical implants. To reduce the risk
of serious or lethal injuries, we re-
commend that persons with medical
implants consult their doctor and the
manufacturer of their medical im-
plant before operating the machine.
Page view 66
1 2 ... 62 63 64 65 66 67 68 69 70 71 72 ... 101 102

Comments to this Manuals

No comments